Flagship
Carbon-reinforced floors for rooftop extensions
Can a lighter precast floor make an additional storey feasible within an existing building’s load budget?
Proposed prototype
We propose a ribbed concrete module with prestressed carbon-fibre reinforcement.
First test
The first study pairs an assessment of one existing building with a prototype floor bay to evaluate anchorage, cracking, deflection and vibration.
Research notes & references
Design targets
The plate between the ribs is aimed at 30–40 mm. Total depth, including the ribs, is reported separately. The comparison is a 220–250 mm reinforced-concrete slab where that thickness fits the reference span and loads. A 60–70% reduction in structural floor mass is a design target, not a measured result. Whether an additional storey is possible without foundation strengthening depends on the assessment of that building.
Method
One existing building and one floor bay would be chosen. The rib layout stays within precast production constraints, and the analysis follows the load path through the existing walls or columns into the foundations. One prototype would be made with a regional precaster and a CFRP supplier. The test covers prestress transfer, anchorage, cracking, deflection, vibration and failure mode. Fire and acoustic evidence would be defined separately before any building use.
Published references
- TU Dresden, C³, alternative element geometry
Documents a 10 cm carbon-concrete slab, span 2.5 m and width 1 m, tested in four-point bending until the carbon grid failed in tension. It does not document a 30–40 mm ribbed plate or a rooftop extension.
- C3-V4.19, parking-garage slabs, 2018–2021
Documents 9 cm specimens with carbon textile loops. It does not document a prestressed ribbed module.